Network Analyzers

 

HP 8720A Network Analyzer (130 MHz to 20 GHz)

Hewlett Packard 8720A Network Analyzer, 130 MHz to 20 GHz

Unit repaired November 16,2007.

Location: Anechoic Chamber  inv #

Operating Manual: 8720B Operating Manual 1990-09-01 Adobe Acrobat File9.31 MB

The 8720A provides simple and complete vector network measurements in a compact and fully integrated microwave network analyzer. Characterize your microwave components and networks accurately, yet economically with this unit. Integration of the 130MHz to 20GHz swept synthesized source, test set, and receiver results in a compact, low cost network analyzer. •>85 dB dynamic range •Built-in vector accuracy enhancement.

 

HP 8720ES S-Parameter Network Analyzer w/Time domain (50 MHz to 20 GHz)

HP / Agilent 8720ES, 8722ES S-Parameter Vector Network Analyzer

.Location: Cito Lab. Inv #CMC6446

Service Guide: 8720ES Service Guide 2002-06-01 Adobe Acrobat File15.1 MB

Reference Guide: 8720ES Reference Guide 2002-06-01 Adobe Acrobat File5.73 MB

User's Guide: 8720ES User's Guide 2002-06-01 Adobe Acrobat File9.11 MB

Programmer's Guide: 8720ES Programmer's Guide 2002-06-01 Adobe Acrobat File10.3 MB

The 8720ES Network Analyzer is a microwave network analyzer featuring a solid-state switching S-parameter test set with full two-port error correction. The unit contains a 55-dB step attenuator as a standard feature for wide output power range of 20 dB. Enhanced response calibration provides improved accuracy for transmission measurements by correcting for source match without the speed penalty of a full two-port calibration. The unit has a frequency range of 50MHz to 20GHz with a resolution of 1Hz.

 

HP 8720ES S-Parameter Network Analyzer w/Time domain (50 MHz to 20 GHz)

HP / Agilent 8720ES, 8722ES S-Parameter Vector Network Analyzer

Location: Undergraduate Lab.inv #

Service Guide: 8720ES Service Guide 2002-06-01 Adobe Acrobat File15.1 MB

Reference Guide: 8720ES Reference Guide 2002-06-01 Adobe Acrobat File5.73 MB

User's Guide: 8720ES User's Guide 2002-06-01 Adobe Acrobat File9.11 MB

Programmer's Guide: 8720ES Programmer's Guide 2002-06-01 Adobe Acrobat File10.3 MB

The 8720ES Network Analyzer is a microwave network analyzer featuring a solid-state switching S-parameter test set with full two-port error correction. The unit contains a 55-dB step attenuator as a standard feature for wide output power range of 20 dB. Enhanced response calibration provides improved accuracy for transmission measurements by correcting for source match without the speed penalty of a full two-port calibration. The unit has a frequency range of 50MHz to 20GHz with a resolution of 1Hz..

 

HP 8722ES S-Parameter Network Analyzer w/Time Domain (50 MHz to 40 GHz)

HP / Agilent 8720ES, 8722ES S-Parameter Vector Network Analyzer

Location: Faraday cage inv #

Service Guide: 8722ES Service Guide 2002-06-01 Adobe Acrobat File15.1 MB

Reference Guide: 8722ES Reference Guide 2002-06-01 Adobe Acrobat File5.73 MB

User's Guide: 8722ES User's Guide 2002-06-01 Adobe Acrobat File9.11 MB

Programmer's Guide: 8722ES Programmer's Guide 2002-06-01 Adobe Acrobat File10.3 MB

The 8722ES vector network analyzer allows complete characterization of RF and microwave components. The 8722ES includes an integrated synthesized source, test set, and a tuned receiver. The built-in S-parameter test set provides a full range of magnitude and phase measurements in both the forward and reverse directions. Built-in vector accuracy enhancement techniques include full two-port, adapter-removal, and optional TRL calibration. Features: • 50 MHz to 40 GHz • 100 dB of dynamic range • Excellent measurement accuracy • Two measurement channels • Four display channels • Frequency and power sweeps • Fast sweep and data transfer speed • Pass/Fail testing, powerful marker functions • Electronic calibration (ECal) • Internal automation with test-sequencing.

 

HP  8410B Network Analyzer (0.11 MHz to 18 GHz)

Location: Undergraduate Lab. Inv#

Operation Manual: 8410B Operation Manual 1982-08-01 Adobe Acrobat File0.99 MB

The 8410B Network Analyzer Mainframe accepts HP plug-ins such as 8412A, 8413A, and 8414A. The unit covers the frequency range from 0.11GHz to 18GHz when used with 8411A/018 Frequency Converter. Mainframe only.

 

HP  8755A Scalar Network Analyzer (10 MHz to 18 GHz)

HP 182T, Spectrum Analyzers, Large Screen Display , Accessories

The 182T Large Screen Display offers versatility and dependable service! It utilizes a large screen display and accepts 8557, 8558, 8559A, or 8755A Spectrum Analyzer series plug- ins. Seeing is believing with an 8 x 10 division internal graticule (1 div = 1.29 cm) and P39 phosphor for a bright and crisp display. Requires one plug-in to complete system, call for great pricing and availability.

Location: Undergraduate Lab. Inv#

 

 

HP 4195A Network/Spectrum Analyzer (10 Hz to 500 MHz)

Location: Graduate Lab. Inv #

Operating Manual: 4195A Operating Manual1990-01-01 Adobe Acrobat File2.25 MB

Maintenance Manual: 4195A Maintenance Manual1989-11-01 Adobe Acrobat File8.83 MB

The 4195A combines both vector network and spectrum analysis in one instrument. The frequency covered is 10Hz through 500MHz with an excellent 0.001Hz resolution for audio, baseband, HF, VHF, and IF applications. It directly measures amplitude ratio, phase, group delay, and spectrum level needed for characterizing linear/non-linear analog circuits or components in communication, telecommunications, consumer electronics and other equipment.

Friday, August 20, 2004